HAZ-SAFE BUILDINGS' PLANNING WORKSHEET

 
1. Interested Party:
 
Name:
Phone:
 
Position/Title:
Cell:
 
Organization/Company:
Fax:
 
Street Address:
Email:
 
City:
Website:
 
State:
Zip Code:
   
2. Potential Use For: (check all that apply)
  Manufacturing: Storage:
  Processing: Clean Room:
  Dispensing: Cooler:
  Testing: Freezer:
  Laboratory: Hot Box:
   
3. Materials in Building:
  Type: Hazard Class: Containers: Quantity:
  (Chemical Name) (Flammable - 1A, 1B, 1C;
Combustible - 11, 111A, 111B, etc.)
(55-Gal. Drums, pallets, tote tanks, ___ gal. process vessels, etc.)  
a.
       
b.
       
c.
       
d.
       
   
4. Building / Room(s) Space Defined:
a.
Building      
Priority dimension External Internal  
Name Width Length Height
b.
Room(s)      
1.
Name Width Length Height
2.
Name Width Length Height
3.
Name Width Length Height
c.
Send / Transmit Sketch(s)
  Plan View(s) Elevation View(s)    
  Attach a drawing or sketch of your plan
   
5. Location on Site:
a.
Fire and Explosion threats only inside building Or inside and outside
b.
Outside - Distance from existing facility/fire rating:
 
Attached / 4 hr.
Adjacent (0 - 10') / 4 hr.
Near (10' - 50') / 2 hr.
Distant (50' - 75') / 1 hr.
 
(past 75') non-combustible steel non-rated
c.
Inside (inplant) - Inside existing or planned facility:
  Size of exterior door or opening x
  Existing overhead crane lift capability:


 
         
6. Cradle (base) of building: (choose one)
 







         
7. Lifting Capabilities:
  Pair 1/4" thick 4" x 12" steel forklift tubes under floor  
  Four (4) universal crane lugs welded to base  
  Four (4) standard wall/roof edge crane lugs  
         
8. Elevated Flooring Type:
  Painted Steel Grate   Galvanized Steel Grate  
  Stainless Steel Grate   Aluminum Grate  
  Fiberglass Grate      
  Grate Opening - Standard 1" x 4" – Upgrade 1/4" x 4" (smallest opening)
  Standard Load Capacity 250 lbs. – Higher lbs.
         
9. Sump Depth:
  4" exceeds EPA 10% (shortest OSHA ramp length)
  6" exceeds EPA and FM 25% (longer ramp)
  8" or higher Reason
         
10. Exterior Wall Finish:
  Standard white painted 10 gauge steel  
  Aggregate panel over above  
  Thin set brick over 10 gauge plate  
  Other, describe
         
11. Wall Separation for Individual Rooms:
  42" high chain link fence framed in tube steel  
  Floor-to-ceiling chain link fence framed in tube steel  
  Floor-to-ceiling bi-directional fire and blast rated  
         
12. Interior Finish:
  Standard porcelain enamel on steel sheet bonded to fire rated gypsum  
  Other, describe
         
13. Doors:
  Non-Rated or Fire Rated    
  Single leaf, swing size x Quantity:  
  Double leaf, swing size x Quantity:  
  Lockset Panic Device Fusible Link closure/hold open device
  Overhead roll-up door size x Quantity:  
  Mounted between frame on exterior
  Motorized  with explosion proof motor
         
14. Low Level Ventilation System:
a.
Fire rated natural, gravity or passive air vent opening(s) through wall (mechanical ventilation requires both air intake and exhaust vent openings with fan(s) on opposite walls as in items #19g & #19h) Quantity:
b.
Posi-ventilation tube integrated within elevated flooring (item #8) and over "V" or sloped trench (item #6) transitioned up to exhaust vent opening above  Quantity:
         
15. Material Handling Expectations:
  User owned hand truck or drum lifter on standard grate with 1" wide x 4" long openings, 250 lbs. load elevated flooring (see item #8)  
  User owned forklift or pallet lifters (consider tighter gate openings and higher than 250 lbs. floor grate)  
  Swivel beam and hoist within building  
  Monorail beam and hoist within building  
  Crane with runway beams, bridge beam and hoist within building  
         
16. Shelving:
 
Width / Depth:
Total linear feet:
         
17. Explosion Relief Systems:
a.
Bottom hinged wall panels Size Quantity  
b.
Blast Shafts:      
 

Through existing wall or roof for inplant building

 
 

Wall mounted for exterior buildings within 50' of another user's facility

 
         
18. Rooftop Crane Lifting Lugs:
       
         
19. Electricals Exterior:
a.
NEMA 3R enclosure Yes Other
b.
Load center size Mfg./Model
c.
Panelboard size Mfg./Model
d.
Transformer required    
e.
Emergency power - on site:  , generator required
f.
Separate alarm and contol box   
g.
Single (#1 fan) on top of outside duct (requires item #13a and optional b)  
h.
Dual (#1 fan and #2 fan) same as above item g.  
         
20. Electricals Interior:
a.
Non-classified industrial purpose    
b.
Class 1, Division 1, Class C & D Standard Other
c.
Voltage: 120V 208V 240V
d.
Phase: Single Three Both
e.
Ceiling light fixtures:      
 

200 watt lamp incandescent, quantity

 

Four 100 watt lamps fluorescent, quantity

f.
Sump liquid spill detection and alarm system. Requires drain pit in item #6. Yes No  
g.
Fan malfunction alarm system Yes No  
h.
Gas malfunction alarm system Yes No  
         
21. Heating, Air Conditioners & Refrigeration:
  Heaters      
  Fan Forced Ceiling Type    
 
Watt Capacity
Quantity
Maintain (°F)
  Convection Wall Hung Type    
 
Watt Capacity
Quantity
Maintain (°F)
  A/C Units      
  Exterior Wall Hung Type    
 
BTU Capacity
Quantity
Maintain (°F)
  Exterior Through-the-Wall Type    
 
BTU Capacity
Quantity
Maintain (°F)
  Refrigeration      
  Split Type System    
 
BTU Capacity
Quantity
Maintain (°F)
         
22. General Components / Systems:
  Drain pit, pipe & hand valve Exterior light fixtures  
  Insulated under sump floor  Outside or inside electrical outlets 
  Drum, pallet & tote tank racks Insulation upgrades 
  Loading ramps  Fire sprinkler piping assembly 
  Lightning protection  Dry chemical fire suppression 
  Grounding  Eye / face wash bowl
  Special paint or coatings  Shower with eye wash station